HRY97 - Explosion-proof high efficiency energy-saving LED lamp
Explosion-proof high efficiency energy-saving LED lamp - HRY97
Standards: CENELEC, IEC, NEC
Zones:
- Zone 1 and Zone 2
- Zone 21 and Zone 22
- Class I, Zone 1 and Zone 2
- Class I, Division 1, Groups B, C, D
Explosion protection:
- IECEX (Gas and dust):
- Ex db eb mb IIC T5/T4 Gb1) Ex tb IIIC T70℃/T90℃ Db1)
- ATEX (Gas and dust):
- II 2 G Ex db eb mb IIC T5/T4 Gb1)
- II 2 D Ex tb IIIC T70℃/T90℃ Db1)
Material:
- Enclosure: Copper-free Aluminium Alloy, powder coated surface, yellow (RAL1021)
- Diffuser: Polycarbonate, stands 4J impact
- Exposed fastener: Stainless steel
LED driver: Wide voltage input, CC-CV (constant current – constant voltage) output, with function of distributed current, constant current, surge-proof and anti-electromagnetic interference, and protection against overcurrent, open circuit, and short circuit.
Lamp:
- Lamp specification: LED module (supplied with the light fittings)
- Lamp power: 20W, 40W, 60W
Color rendering index: ≥80
Colour temperature: 5000K
Rated luminous flux: 2500~7000lm
Rated voltage: 100-277V AC 50/60Hz; 130~250V DC
Earthing protection: M4 (internal & external earth bolts)
Degree of protection:IP66
Ambient temperature:-40℃ ~+60℃ (+58℃)(+40℃)1)
Terminal: 3 x 1.5~4mm2 (L+N+PE)
Cable entries: 2 x M25 x 1.5 plugs
Weight: 2.9kg~7.7kg
Size: 123x1095x138mm
Mounting:X: ceiling type, B: wall type, G: pendant pole type, W: bend pole type, F: flange type, H: fence type, QT: Derrick-specific type
Emergency unit: with emergency controller and battery pack
Emergency power: 20W x 70%, 40W x 35%, 60W x 23%
Emergency starting time: 0.3s
Charging time: 24h
Emergency lighting time: 90min(180min is optional)
Battery: Ni-CD (Ni-MH is optional)